-- *****************************************************************************
-- Juniper-ES2-Registry
--
-- Juniper Networks enterprise SNMP MIB.
-- Registry for the second generation E-series edge router product entities.
--
-- Copyright (c) 2003-2006 Juniper Networks, Inc.
-- All Rights Reserved.
-- *****************************************************************************Juniper-ES2-Registry DEFINITIONS::=BEGINIMPORTSMODULE-IDENTITY,OBJECT-IDENTITYFROM SNMPv2-SMI
juniAdmin
FROM Juniper-Registry;juniES2Registry MODULE-IDENTITYLAST-UPDATED"200612182106Z"-- 18-Dec-06 04:06 PM ESTORGANIZATION"Juniper Networks, Inc."CONTACT-INFO" Juniper Networks, Inc.
Postal: 10 Technology Park Drive
Westford, MA 01886-3146
USA
Tel: +1 978 589 5800
Email: mib@Juniper.net"DESCRIPTION"Juniper second generation E-series product family system-specific
object identification values. This module defines AutonomousType (OID)
values for all the physical entity types (entPhysicalVendorType). This
module will be updated whenever a new type of module or other hardware
becomes available in second generation E-series systems."-- Revision HistoryREVISION"200612182106Z"-- 18-Dec-06 04:06 PM EST - JUNOSe 8.3
DESCRIPTION"Added GE20 IOA Support."REVISION"200611240913Z"-- 24-Nov-06 04:13 AM EST - JUNOSe 8.2DESCRIPTION"Added E120 product family support."REVISION"200601061806Z"-- 06-Jan-06 01:06 PM EST - JUNOSe mainDESCRIPTION"Added LM10 Access Support."REVISION"200509151346Z"-- 15-Sep-05 09:46 AM EDT - JUNOSe 7.2DESCRIPTION"Added LM10 Uplink Support."REVISION"200508191158Z"-- 19-Aug-05 06:58 AM EST - JUNOSe mainDESCRIPTION"Added GE8 Support."REVISION"200507291826Z"-- 29-Jul-05 02:26 PM EDT - JUNOSe 7.0.1DESCRIPTION"renamed entity objects, reordered to match rsSystem.mi2 and removed
obsoleted boards."REVISION"200412231158Z"-- 23-Dec-04 06:58 AM EST - JUNOSe mainDESCRIPTION"Updated for second generation E-series hardware."REVISION"200412061021Z"-- 06-Dec-04 05:21 AM EDT - JUNOSe main
DESCRIPTION"Renamed E2 MIB objects to ES2 MIB objects."REVISION"200405191742Z"-- 19-May-04 01:42 PM EDT - JUNOSe 6.0DESCRIPTION"Updated for revised E320 hardware."REVISION"200308182027Z"-- 18-Aug-03 04:27 PM EDT - JUNOSe 6.0DESCRIPTION"Initial version of this SNMP management information module."::={ juniAdmin 3}-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
-- Second generation E-series physical entity identifiers.
-- The OID values under juniES2EntPhysicalType are used by the SNMP agent in
-- the second generation E-series product as the AutonomousType values for the
-- entPhysicalVendorType varbinds for the second generation E-series objects in
-- the entPhysicalTable.
-- +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++juniES2EntPhysicalType OBJECTIDENTIFIER::={ juniES2Registry 1}--
-- Chassis class
--es2Chassis OBJECT-IDENTITYSTATUScurrent
DESCRIPTION"The vendor type ID for a second generation E-series chassis. This
identifies an 'overall' physical entity for any second generation
E-series system."::={ juniES2EntPhysicalType 1}e320BaseChassis OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 base chassis with 12 slots for line modules - includes chassis,
midplane, DC PDU, and fan tray. The E320 system uses a carrier-class
design with a passive midplane, active front-insert line modules(LM)
and rear-insert input/output adapters(IOA)."::={ es2Chassis 1}e120BaseChassis OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E120 base chassis with 6 slots for line modules - includes chassis,
midplane, DC PDU, and fan tray. The E120 system uses a carrier-class
design with a passive midplane, active front-insert line modules(LM)
and rear-insert input/output adapters(IOA)."::={ es2Chassis 2}--
-- Fan class
--es2FanAssembly OBJECT-IDENTITYSTATUScurrent
DESCRIPTION"The vendor type ID for a second generation E-series fan assembly."::={ juniES2EntPhysicalType 2}e320PrimaryFanTray OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 fan tray with 8 fans."::={ es2FanAssembly 1}e320AuxiliaryFanTray OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 fan tray with 8 fans."::={ es2FanAssembly 2}e120PrimaryFanTray OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E120 fan tray with 9 fans."::={ es2FanAssembly 3}--
-- Power Supply class
--es2PowerInput OBJECT-IDENTITYSTATUScurrentDESCRIPTION"The vendor type ID for a second generation E-series power distribution
module."::={ juniES2EntPhysicalType 3}e320DcPowerDistributionUnit OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 DC power distribution unit (PDU)."::={ es2PowerInput 1}--
-- Backplane class
--es2Midplane OBJECT-IDENTITYSTATUScurrentDESCRIPTION"The vendor type ID for a second generation E-series midplane."::={ juniES2EntPhysicalType 4}e320Midplane OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 chassis midplane."::={ es2Midplane 1}e120Midplane OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E120 chassis midplane."::={ es2Midplane 2}--
-- Module class - integrated system controller/switch fabric
--es2SrpModule OBJECT-IDENTITYSTATUScurrentDESCRIPTION"The vendor type ID for a second generation E-series system controller/
switch fabric module."::={ juniES2EntPhysicalType 5}e320Srp100 OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 100Gb SRP - The Switch Route Processor (SRP)
is responsible for running the routing protocols as well as
overall system control. The SRP also contains a switch fabric
slice that is responsible for packet forwarding."::={ es2SrpModule 1}e320Srp320 OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 320Gb SRP - The Switch Route Processor (SRP)
is responsible for running the routing protocols as well as
overall system control. The SRP also contains a switch fabric
slice that is responsible for packet forwarding."::={ es2SrpModule 2}e120Srp120 OBJECT-IDENTITY
STATUScurrentDESCRIPTION"E120 120Gb SRP - The Switch Route Processor (SRP)
is responsible for running the routing protocols as well as
overall system control. The SRP also contains a switch fabric
slice that is responsible for packet forwarding."::={ es2SrpModule 3}--
-- Module class - switch fabric
--es2SwitchFabricModule OBJECT-IDENTITYSTATUScurrentDESCRIPTION"The vendor type ID for a second generation E-series switch fabric
module."::={ juniES2EntPhysicalType 6}e320Sfm100 OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 100Gb switch fabric module. The SFM functions include buffer
management, queuing, scheduling and packet processing."::={ es2SwitchFabricModule 1}e320Sfm320 OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 320Gb switch fabric module. The SFM functions include buffer
management, queuing, scheduling and packet processing."::={ es2SwitchFabricModule 2}e120Sfm120 OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E120 120Gb switch fabric module. The SFM functions include buffer
management, queuing, scheduling and packet processing."::={ es2SwitchFabricModule 3}--
-- Adapter class - system controller I/O Adapter
--es2SrpIoa OBJECT-IDENTITYSTATUScurrentDESCRIPTION"The vendor type ID for the system controller I/O adapter for a second
generation E-series system."::={ juniES2EntPhysicalType 7}e320SrpIoa OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 SRP IOA. This card provides clocking functions as well as
management and alarm interfaces."::={ es2SrpIoa 1}--
-- Module class - forwarding
--es2ForwardingModule OBJECT-IDENTITY
STATUScurrentDESCRIPTION"The vendor type ID for a second generation E-series forwarding module."::={ juniES2EntPhysicalType 8}es2Lm4 OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 4Gb (series 1) line module. This Line Module supports both
uplink and customer facing IOAs and is responsible for
processing data traffic."::={ es2ForwardingModule 1}es2Lm10Uplink OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 10Gb (series 2) uplink line module. This Line Module is
primarily focused on uplink IOAs and is responsible for
processing data traffic."::={ es2ForwardingModule 2}es2Lm10 OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 10Gb (series 3) line module. This Line Module supports
both uplink and customer facing IOAs and is responsible for
processing data traffic."
::={ es2ForwardingModule 3}--
-- Adapter class - forwarding I/O adapter
--es2ForwardingIoa OBJECT-IDENTITYSTATUScurrentDESCRIPTION"The vendor type ID for a second generation E-series I/O adapter for a
forwarding module."::={ juniES2EntPhysicalType 9}es2Ge4S1Ioa OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 GE-4 IOA. This is a series 1, half-height, single wide IOA
with 4 physical interfaces that require pluggable GE interfaces. This
IOA uses the full capacity of a Series 1 line module."::={ es2ForwardingIoa 1}es2Oc48Stm16PosS1Ioa OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 OC48/STM16 POS IOA. This is a series 1, half-height,
single wide IOA with 1 physical interface that requires a pluggable
OC48/STM16 interface."::={ es2ForwardingIoa 2}es2ServiceS1Ioa OBJECT-IDENTITY
STATUScurrentDESCRIPTION"E320 service IOA. This is a series 1, full-height, single
wide IOA and does not support any physical interfaces."::={ es2ForwardingIoa 3}es2Oc3Stm1x8AtmS1Ioa OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 OC3/STM1-8 ATM IOA. This is a series 1, half-height,
single wide IOA that supports 8 physical interfaces that require
pluggable OC3/STM1 interfaces. This IOA can be combined with other
half-height IOAs (except those that use the full capacity of a slot's
bandwidth such as the GE-4 IOA)."::={ es2ForwardingIoa 4}es2RedundancyS1Ioa OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 redundancy IOA. This is a series 1, full-height, single
wide IOA and does not support any physical interfaces."::={ es2ForwardingIoa 5}es2Oc12Stm4x2PosS1Ioa OBJECT-IDENTITYSTATUScurrent
DESCRIPTION"E320 OC12/STM4-2 POS IOA. This is a series 1, half-height,
single wide IOA that supports 2 physical interfaces that require
pluggable OC12/STM4 interfaces. This IOA can be combined with other
half-height IOAs (except those that use the full capacity
of a slot's bandwidth such as the GE-4 IOA)."::={ es2ForwardingIoa 6}es2Oc12Stm4x2AtmS1Ioa OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 OC12/STM4-2 ATM IOA. This is a series 1, half-height,
single wide IOA that supports 2 physical interfaces that require
pluggable OC12/STM4 interfaces. This IOA can be combined with other
half-height IOAs (except those that use the full capacity
of a slot's bandwidth such as the GE-4 IOA)."::={ es2ForwardingIoa 7}es2dash10GeS1Ioa OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 10GE IOA. This is a series 1, full-height, single wide
IOA that supports 2 physical interface that requires a pluggable
10GE interface."::={ es2ForwardingIoa 8}es2Ge8S1Ioa OBJECT-IDENTITY
STATUScurrentDESCRIPTION"E320 GE-8 IOA. This is a series 1, half-height, single wide IOA
that supports 8 physical interfaces that require pluggable GE
transceivers. This IOA will support a configuration of 8 active
or 4 active + 4 standby interfaces."::={ es2ForwardingIoa 9}es2dash10GePrS2Ioa OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 10GE IOA with port redundancy (PR). This is a series 2,
full-height, single wide IOA that supports 2 physical
interfaces (1 active + 1 standby) that require pluggable 10GE
transceivers."::={ es2ForwardingIoa 10}es2Ge20S2Ioa OBJECT-IDENTITYSTATUScurrentDESCRIPTION"E320 GE-20 IOA. This is a series 2, full-height, single wide IOA
that supports 20 physical interfaces that require pluggable GE
transceivers. This IOA will support a configuration of 20 active
or 10 active + 10 standby interfaces."::={ es2ForwardingIoa 11}
END